I’ve gotta say: this is the best investment I've made in my prep. I was able to study on my lunch breaks thanks to the PDF format and passed the MS-721 in just under two weeks of studying. The accuracy is just incredible.

Five of the 85 questions in this pack
What should be considered when using a direct air handler for a data centre?
- A. Cost of operation as power consumption on these units tend to be higher compared to traditional air conditioning technology.
- B. Temperature, humidity and contamination of the outdoor environment.
- C. Space available inside the computer rooms as the air handler space requirement for the inside the Computer room is quite large.
- D. The availability of three-phase power due to the high power requirements of these air handler units.
Show answer and explanation
Correct answer: B. Temperature, humidity and contamination of the outdoor environment.
A direct air handler brings outside air into the data centre, so the temperature, humidity and contamination of that outdoor air decide whether it can be used safely.
Why the other options are wrong
- A. Running cost matters, but it is not the main thing to check when outside air is brought straight into the room.
- C. Space inside the computer room is not the key consideration for this cooling method.
- D. Three-phase power is a general supply matter, not the issue specific to direct air handling.
Which of statements below is true?
- A. Single-mode cabling can use both LED and laser as a light source.
- B. Single-mode cabling is more expensive than multi-mode cabling.
- C. Multi-mode cabling can cross longer distances.
- D. Multi-mode cabling is more expensive than single-mode cabling.
Show answer and explanation
Correct answer: B. Single-mode cabling is more expensive than multi-mode cabling.
Single-mode cabling is the more expensive option, mainly because it needs laser-based equipment, while multi-mode is cheaper and used over shorter distances.
Why the other options are wrong
- A. Single-mode links use a laser as the light source, not an LED.
- C. It is single-mode cabling that crosses longer distances, not multi-mode.
- D. This reverses the cost relationship: multi-mode is the cheaper of the two.
What type of heat does ICT equipment generate?
- A. Latent heat
- B. Sensible heat
- C. Both latent and sensible heat
- D. Radiant heat
Show answer and explanation
Correct answer: B. Sensible heat
IT equipment turns electrical power into dry heat that raises the air temperature without changing its moisture content. That is sensible heat.
Why the other options are wrong
- A. Latent heat relates to a change of moisture, such as humidifying or dehumidifying, not to IT load.
- C. IT equipment does not add latent heat, so it is not both.
- D. Radiant heat is not how IT equipment loads are classified for cooling.
What is the main difference between an ATS and a STS?
- A. STS has a very fast switching time (e.g. less than 20 ms).
- B. STS has a slow switching time (e.g. more than 50 ms).
- C. STS is a make-before-break switch and an ATS is a break-before-make switch.
- D. STS is for high voltage and an ATS is for low voltage.
Show answer and explanation
Correct answer: A. STS has a very fast switching time (e.g. less than 20 ms).
A static transfer switch (STS) uses electronic switching and moves the load in a few milliseconds, well under 20 ms. An automatic transfer switch (ATS) is slower, so switching speed is the main difference.
Why the other options are wrong
- B. This reverses the two: the STS is the fast one.
- C. Make-before-break against break-before-make is not the defining difference between the two; switching speed is.
- D. Neither is defined by voltage class; both are used at various voltages.
What causes most fires in data centres?
- A. Equipment overheating, loose connections, dead shorts
- B. Air conditioner temperature settings, fuel spills, packing material
- C. Lightning strikes, harmonic distortion air conditioner temperature settings
- D. Low relative humidity, lightning strikes air conditioner temperature settings
Show answer and explanation
Correct answer: A. Equipment overheating, loose connections, dead shorts
Most data centre fires are electrical in origin. Overheating equipment, loose connections and dead shorts all generate enough heat to ignite cable insulation and components.
Why the other options are wrong
- B. Air conditioner temperature settings, fuel spills and packing material are not the main causes of data centre fires.
- C. Lightning strikes, harmonic distortion and air conditioner temperature settings are not the main causes of data centre fires.
- D. Low relative humidity raises the risk of static electricity and is not a main cause of fires.
Try EXIN CDCP free first
85 questions in the full pack- Free sample: 23 questions 23 real questions, every answer explained, in one PDF. Download PDF
- Full pack, $39.00 USD paid once All 85 questions, every answer explained, plus a questions-only PDF. Updates for life.Get the full pack
CDCP exam questions with answers: all 85 for the EXIN EPI Certified Data Centre Professional exam.
This pack is the complete set, covering every part of the CDCP main subjects. Download the free sample to see the question style first.
- 85 exam practice questions: mapped to the CDCP main subjects
- Complete answers and explanations, including why every wrong option is wrong
- Questions-only PDF: for timed practice
- Email delivery: sent to your email within 24 hours
- Free monthly updates for life
You pay for this PDF once, with a refund if you fail anyway.
CDCP exam questions: the short answers
How many questions are on the CDCP exam?
EXIN lists 40 multiple-choice questions and 1 hour. The exam is closed book and no electronic equipment is allowed.
What is the pass mark?
The pass mark is 68%.
Is training required?
Yes. EXIN lists training as mandatory, and the required reading is the course material from the trainer.
What makes this exam hard
Three subjects cover the whole exam: Facilities, Operations and Management. EXIN publishes no weights, so study all three evenly, and use the free sample to see how physical topics such as cooling, cabling, earthing and power switching are asked.
The questions test practical facts a data centre professional is expected to know, for example which kind of heat IT equipment produces or what separates a static transfer switch from an automatic one. With 40 questions in 60 minutes you have time for each, but not for guessing.
Before you buy
Free questions
Real EXIN CDCP questions are free on the site, each with the answer explained.
What you get for $39.00 USD
- All 85 questions, each with the correct answer and why the other options are wrong
- 2 PDFs: the full pack, plus a questions-only copy for timed practice
- Delivered to your email within 24 hours
- Updated once a month, with free updates for life, emailed to the address you used at checkout
- Paid once
How a question works
What type of heat does ICT equipment generate?
- ALatent heat
- BSensible heat
- CBoth latent and sensible heat
- DRadiant heat
Why B is right IT equipment turns electrical power into dry heat that raises the air temperature without changing its moisture content.
What do I get?
Every pack comes as 2 PDFs: one with every answer explained, and a questions-only copy for timed practice. This pack is delivered to your email within 24 hours, and every pack includes free updates for life.
How often are the questions updated?
Question sets are updated once a month. The date of the latest update is shown on every exam page.
Will I receive updates after purchasing?
Yes. All PDF purchases include lifetime updates. Updated versions are emailed automatically to the email address used during checkout.
What if an answer looks wrong?
We correct mistakes as we find them, and the monthly update sends those fixes to you. No question bank this size is ever completely flawless, so if something still looks off to you, check it against the vendor's own documentation and send it to support@dailydebian.com. We reply to every message, and the fix ships in the next update, free, for life.
Are your materials enough to pass the exam?
Most candidates use them as their main practice source. If you study with them and still fail, we refund you in full.
What happens if I fail my exam?
You get your money back. Email support@dailydebian.com within 14 days of receiving your results, with your order number and a copy of your official score report showing the fail. Requests are reviewed within 5 to 7 business days and approved refunds go back to the original payment method. Full terms are in the refund policy.
Do you have discount codes?
Yes, when you buy more than one exam pack. For 2 packs, use code BUY2 for 15% off. For 3 or more packs, use code BUY3 for 20% off. Enter the code in the discount box at checkout.
What payment methods do you accept?
Visa, Mastercard, American Express, UnionPay, Apple Pay, Google Pay, Shop Pay and PayPal. All prices are shown in your local currency at checkout.
Do you offer shipping?
No. All products are digital downloads. There is no physical shipping.
I did not receive my order after payment.
Contact support@dailydebian.com with your order number and payment confirmation details.