vSAN Storage Policy Practice: FTT, RAID and Minimum Hosts

Free vSAN storage policy practice for the VCP-DCV, VCP-VCF and VCP-VVF exams. Each invented policy sets Failures to tolerate, RAID-1 or RAID-5/6 and OSA or ESA: work out the capacity a disk needs, the minimum hosts or fault domains, or whether the cluster allows it, and Check my answer names the slip, such as the OSA RAID-5 rule on ESA or two copies for FTT 2.

Version 
Architecture 
Failures to tolerate 
Cluster 
Failure tolerance method 

Check your answer to see the working.

Each question names the Broadcom page it uses: vSAN 8.0 or VCF 9.1. OSA rules count fault domains; the VCF 9.1 ESA table counts hosts.

Every policy is invented. Spare hosts for rebuilds, slack space, deduplication, compression and stretched clusters are left out.

Practise the exams

Start with the free real exam questions for your exam, then get the full pack.

2V0-21.23 VCP-DCV
110 real exam questionsUS$39
Free: 28 questionsGet the full pack
2V0-17.25 VCP-VCF Administrator
100 real exam questionsUS$39
Free: 25 questionsGet the full pack
2V0-16.25 VCP-VVF Administrator
60 real exam questionsUS$39
Free: 22 questionsGet the full pack

vSAN storage policy FAQ

The policy rules in short
  • Capacity, vSAN 8.0 table: RAID-1 FTT 1 is 2x, FTT 2 is 3x; RAID-5 on OSA is 1.33x; RAID-6 is 1.5x.
  • Capacity, VCF 9.1 ESA table: RAID-1 is 2x, 3x or 4x for FTT 1, 2 or 3; RAID-5 (2+1) is 1.5x; RAID-5 (4+1) is 1.25x; RAID-6 (4+2) is 1.5x.
  • Minimum hosts, VCF 9.1 ESA table: RAID-1 needs 3, 5 or 7; RAID-5 (2+1) needs 3; 4+1 and RAID-6 need 6.
  • OSA: RAID-5 needs four or more fault domains and RAID-6 six or more, all-flash only.
  • Erasure coding: RAID-5 is FTT 1, RAID-6 is FTT 2, and FTT 3 is not supported.
  • ESA RAID-5 layout: 4+1 with six or more fault domains, 2+1 with five or fewer.
How much capacity does a vSAN storage policy need?

The vSAN 8.0 page gives it for 100 GB of data: RAID-1 with FTT 1 needs 200 GB, RAID-1 with FTT 2 needs 300 GB, RAID-5 on OSA with four fault domains needs 133 GB and RAID-6 with six fault domains needs 150 GB. So multiply the disk size by 2, 3, 1.33 or 1.5.

How many hosts does FTT 2 need on vSAN ESA?

The VCF 9.1 ESA table lists RAID-1 with FTT 2 as 3 mirrors, 3x, with a minimum of 5 hosts, and RAID-6 (4+2) as 1.5x with a minimum of 6 hosts. FTT 1 RAID-1 needs 3 hosts and FTT 3 RAID-1 needs 7.

Why does RAID-5 need four fault domains on OSA but three hosts on ESA?

Both pages say you can configure RAID 5 on all-flash clusters with four or more fault domains, and the vSAN 8.0 table lists OSA RAID 5 with four fault domains. The ESA tables list RAID-5 (2+1) from 3 hosts. The drill uses the four fault domain rule for OSA only.

When does vSAN ESA use RAID-5 (2+1) or RAID-5 (4+1)?

With six or more fault domains, five RAID 5 components are listed; with five or fewer, three. The VCF 9.1 table gives RAID-5 (2+1) as 1.5x from 3 hosts and RAID-5 (4+1) as 1.25x from 6 hosts, so the drill uses 2+1 on 3 to 5 hosts and 4+1 on 6 or more.

Can RAID-5 or RAID-6 run on a hybrid vSAN cluster?

The pages state RAID 5 and RAID 6 for all-flash clusters, so in this drill an OSA hybrid cluster with erasure coding is not supported.

Which Failures to tolerate values does erasure coding support?

RAID 5 is Failure tolerance method RAID-5/6 (Erasure Coding) with Failures to tolerate 1, and RAID 6 is the same method with 2. Erasure coding does not support a Failures to tolerate value of 3, so FTT 3 needs RAID-1 (Mirroring).

How many copies does FTT 2 mirroring keep?

Three. The VCF 9.1 ESA table lists FTT 2 RAID-1 as 3 mirrors with a 3x protection overhead, so a 200 GB disk needs 600 GB.

Does the drill count spare hosts for rebuilds or slack space?

No. The two pages it uses do not state a rebuild headroom rule, so it is left out, along with slack space, deduplication, compression, stretched clusters and witness hosts.

Are vSAN storage policies on the VCP exams?

The VMware vSphere 8.x Professional (2V0-21.23) exam guide lists 1.3.4 Describe storage policies and 7.4.2 Create virtual machine storage policies. The VCF 9.0 Administrator (2V0-17.25) and VVF 9.0 Administrator (2V0-16.25) guides list Given a scenario, configure vSAN Storage policies under objective 2.3.

Sources

Checked 21 November 2026 against the Broadcom TechDocs pages for VMware vSAN 8.0 and VMware Cloud Foundation 9.1 and the Broadcom exam guides.

More free tools