vSAN Storage Policy Practice: FTT, RAID and Minimum Hosts
Free vSAN storage policy practice for the VCP-DCV, VCP-VCF and VCP-VVF exams. Each invented policy sets Failures to tolerate, RAID-1 or RAID-5/6 and OSA or ESA: work out the capacity a disk needs, the minimum hosts or fault domains, or whether the cluster allows it, and Check my answer names the slip, such as the OSA RAID-5 rule on ESA or two copies for FTT 2.
Each question names the Broadcom page it uses: vSAN 8.0 or VCF 9.1. OSA rules count fault domains; the VCF 9.1 ESA table counts hosts.
Every policy is invented. Spare hosts for rebuilds, slack space, deduplication, compression and stretched clusters are left out.
Practise the exams
Start with the free real exam questions for your exam, then get the full pack.
vSAN storage policy FAQ
The policy rules in short
- Capacity, vSAN 8.0 table: RAID-1 FTT 1 is 2x, FTT 2 is 3x; RAID-5 on OSA is 1.33x; RAID-6 is 1.5x.
- Capacity, VCF 9.1 ESA table: RAID-1 is 2x, 3x or 4x for FTT 1, 2 or 3; RAID-5 (2+1) is 1.5x; RAID-5 (4+1) is 1.25x; RAID-6 (4+2) is 1.5x.
- Minimum hosts, VCF 9.1 ESA table: RAID-1 needs 3, 5 or 7; RAID-5 (2+1) needs 3; 4+1 and RAID-6 need 6.
- OSA: RAID-5 needs four or more fault domains and RAID-6 six or more, all-flash only.
- Erasure coding: RAID-5 is FTT 1, RAID-6 is FTT 2, and FTT 3 is not supported.
- ESA RAID-5 layout: 4+1 with six or more fault domains, 2+1 with five or fewer.
How much capacity does a vSAN storage policy need?
The vSAN 8.0 page gives it for 100 GB of data: RAID-1 with FTT 1 needs 200 GB, RAID-1 with FTT 2 needs 300 GB, RAID-5 on OSA with four fault domains needs 133 GB and RAID-6 with six fault domains needs 150 GB. So multiply the disk size by 2, 3, 1.33 or 1.5.
How many hosts does FTT 2 need on vSAN ESA?
The VCF 9.1 ESA table lists RAID-1 with FTT 2 as 3 mirrors, 3x, with a minimum of 5 hosts, and RAID-6 (4+2) as 1.5x with a minimum of 6 hosts. FTT 1 RAID-1 needs 3 hosts and FTT 3 RAID-1 needs 7.
Why does RAID-5 need four fault domains on OSA but three hosts on ESA?
Both pages say you can configure RAID 5 on all-flash clusters with four or more fault domains, and the vSAN 8.0 table lists OSA RAID 5 with four fault domains. The ESA tables list RAID-5 (2+1) from 3 hosts. The drill uses the four fault domain rule for OSA only.
When does vSAN ESA use RAID-5 (2+1) or RAID-5 (4+1)?
With six or more fault domains, five RAID 5 components are listed; with five or fewer, three. The VCF 9.1 table gives RAID-5 (2+1) as 1.5x from 3 hosts and RAID-5 (4+1) as 1.25x from 6 hosts, so the drill uses 2+1 on 3 to 5 hosts and 4+1 on 6 or more.
Can RAID-5 or RAID-6 run on a hybrid vSAN cluster?
The pages state RAID 5 and RAID 6 for all-flash clusters, so in this drill an OSA hybrid cluster with erasure coding is not supported.
Which Failures to tolerate values does erasure coding support?
RAID 5 is Failure tolerance method RAID-5/6 (Erasure Coding) with Failures to tolerate 1, and RAID 6 is the same method with 2. Erasure coding does not support a Failures to tolerate value of 3, so FTT 3 needs RAID-1 (Mirroring).
How many copies does FTT 2 mirroring keep?
Three. The VCF 9.1 ESA table lists FTT 2 RAID-1 as 3 mirrors with a 3x protection overhead, so a 200 GB disk needs 600 GB.
Does the drill count spare hosts for rebuilds or slack space?
No. The two pages it uses do not state a rebuild headroom rule, so it is left out, along with slack space, deduplication, compression, stretched clusters and witness hosts.
Are vSAN storage policies on the VCP exams?
The VMware vSphere 8.x Professional (2V0-21.23) exam guide lists 1.3.4 Describe storage policies and 7.4.2 Create virtual machine storage policies. The VCF 9.0 Administrator (2V0-17.25) and VVF 9.0 Administrator (2V0-16.25) guides list Given a scenario, configure vSAN Storage policies under objective 2.3.
Sources
- Broadcom TechDocs, VMware vSAN 8.0: Using RAID 5 or RAID 6 Erasure Coding in vSAN Cluster: the table Capacity Required to Store and Protect Data at Different RAID Levels, the four and six fault domain rules for all-flash clusters, twice and 1.33 times the disk size, the FTT values for RAID 5 and RAID 6, no FTT 3 with erasure coding, and the ESA RAID 5 component counts.
- Broadcom TechDocs, VMware Cloud Foundation 9.1: Selecting the Best RAID Configuration for a vSAN Storage Cluster: the vSAN ESA RAID Options table (FTT, RAID type, protection overhead, minimum hosts) and the same rules for RAID 5 and RAID 6.
- Broadcom: VMware vSphere 8.x Professional (2V0-21.23) exam guide: 1.3.4, 1.3.5, 1.7.2 and 7.4.2.
- Broadcom: VMware Cloud Foundation 9.0 Administrator (2V0-17.25) exam guide and VMware vSphere Foundation 9.0 Administrator (2V0-16.25) exam guide: objective 2.3, configure vSAN Storage policies.
- Checked 21 November 2026. The tool's own approach: every policy is invented; each question uses one page, named on screen; OSA questions count fault domains and VCF 9.1 ESA questions count hosts, as the pages do; the four fault domain rule is used for OSA only; vSAN 8.0 ESA RAID-5 is left out because its table rows and its component rule differ at five fault domains; for OSA RAID-5 the drill accepts 1.33x the disk size to within 1 GB. An independent re-solver that reads both tables from the saved pages agreed with the drill on 36,000 generated questions.
Checked 21 November 2026 against the Broadcom TechDocs pages for VMware vSAN 8.0 and VMware Cloud Foundation 9.1 and the Broadcom exam guides.
- DrillvSphere shares and reservations practiceWork out what each VM gets from shares, reservations, limits and resource pools on new hosts.
- DrillvSphere HA slot policy practiceWork out slot size, slots per host and Current Failover Capacity on new clusters.
- DrillAWS IAM policy evaluation practiceDecide if a request is allowed or denied across identity policies, bucket policies, SCPs and permissions boundaries, and pick what decides it.