Question 1

If an interface is down and showing a "down" (red) status, which two of the following points need to be reviewed? (Choose two.)

  • A. Check the cable for physical connectivity problems.
  • B. Check the parent device to ensure it is operating.
  • C. Check sensors for the interface using hardware health.
  • D. Create custom poller for the interface using device studio.
Show answer and explanation ▾

Correct answer: A, B

A down interface is most often a physical or upstream problem. Checking the cable rules out a failed or unplugged link, and checking the parent device confirms that the equipment the interface depends on is still running.

Why the other options are wrong:

  • C. Hardware health sensors report on components such as fans and power supplies, not on why an interface is down.
  • D. Building a custom poller adds a new statistic and does nothing to diagnose a down interface.

Question 2

A problem occurred on the main polling engine and the server fails. It is noted that statistics for the networking devices polled by a universal device poller (UDP) custom monitor are missing.

Which two of the following reasons are possible causes of this event? (Choose two.)

  • A. data collection for any UDPs stops on the server
  • B. networking devices are not assigned to the UDP
  • C. UDPs do not collect data from failover or hot standby engines
  • D. UDPs are tied to the polling engine on which they are hosted
Show answer and explanation ▾

Correct answer: A, D

Universal Device Pollers are tied to the polling engine on which they are hosted. When that engine's server fails, collection for its custom pollers stops, so the statistics for those devices go missing.

Why the other options are wrong:

  • B. The pollers were collecting before the failure, so the devices were already assigned.
  • C. This is not the documented reason; the limitation is that each poller belongs to the engine that hosts it.

Question 3

Which two of the following requirements are needed to receive flow data in hybrid cloud observability? (Choose two.)

  • A. add nodes directly to NetFlow endpoints
  • B. monitor interfaces under flow sources
  • C. server is listening on port 1434
  • D. server is listening on port 2055
Show answer and explanation ▾

Correct answer: B, D

Flow data is accepted only from interfaces that are monitored and listed under flow sources, and the collector must be listening on its default flow port, 2055.

Why the other options are wrong:

  • A. Nodes are not added to NetFlow endpoints; their monitored interfaces are managed as flow sources.
  • C. Port 1434 is used by SQL Server, not by the flow collector.

Question 4

Which VPN vendor allows network insight to check site to site VPN connections?

  • A. AnyConnect
  • B. Citrix Gateway
  • C. Global Protect
  • D. OpenVPN
Show answer and explanation ▾

Correct answer: C

Network Insight for Palo Alto firewalls shows site to site VPN tunnels along with GlobalProtect client VPN sessions, so GlobalProtect is the vendor VPN tied to that feature.

Why the other options are wrong:

  • A. AnyConnect is a Cisco remote access client and is not the vendor option tied to this site to site view.
  • B. Citrix Gateway is not covered by Network Insight VPN monitoring.
  • D. OpenVPN is not covered by Network Insight VPN monitoring.

Question 5

Which custom poller supports interface traffic, UPS battery status, and CPU temperature?

  • A. device studio
  • B. hardware health
  • C. universal device poller (UDP)
  • D. virtualization integration
Show answer and explanation ▾

Correct answer: C

The Universal Device Poller builds custom monitors for almost any SNMP statistic from its MIB and OID. Interface traffic, UPS battery status and CPU temperature are the standard examples of what it can poll.

Why the other options are wrong:

  • A. Device Studio builds pollers for a small set of technologies such as CPU and memory and node details.
  • B. Hardware health is a built-in sensor feature, not a custom poller, and it does not poll interface traffic.
  • D. Virtualization integration monitors hypervisors and virtual machines and is not a custom poller.

Question 6

A network router node using ICMP polling has a green status icon and shows basic information (i.e., status) but is not showing more detailed statistics.

What might resolve this issue?

  • A. Edit the node properties to verify proper polling credentials.
  • B. Run ping tests to verify communication.
  • C. Switch polling to SNMP to gather additional polling statistics.
  • D. Unmanage and re-manage the node.
Show answer and explanation ▾

Correct answer: C

ICMP polling returns only status, response time and packet loss. Switching the node to SNMP lets the platform collect detailed statistics such as CPU, memory and interface data.

Why the other options are wrong:

  • A. ICMP polling uses no credentials, so there are none to verify.
  • B. The green status already shows that ping communication works.
  • D. Unmanaging and re-managing the node does not change what ICMP can collect.

Question 7

Probing interval determines how often and how long information is polled from the network path.

Which two of the following statements are true regarding probing intervals? (Choose two.)

  • A. probing less frequently allows the data to update more slowly and increases data accuracy
  • B. probing less frequently allows the data to update faster hut decreases data accuracy
  • C. probing more frequently allows the data to update faster but decreases data accuracy
  • D. probing more frequently allows the data to update more slowly and increases data accuracy
Show answer and explanation ▾

Correct answer: A, C

The probing interval is a trade-off between speed and accuracy. Probing less often updates the data more slowly but gives a more accurate picture, while probing more often updates the data faster at the cost of accuracy.

Why the other options are wrong:

  • B. Probing less frequently makes the data update more slowly, not faster.
  • D. Probing more frequently makes the data update faster, not more slowly.

Question 8

Which statement regarding IP address group synchronization between NTA and IPAM is true?

  • A. It is a one-way sync from IPAM to NTA.
  • B. It is a one-way sync from NTA to IPAM.
  • C. NTA and IPAM IP address groups only exist separately.
  • D. Once synced, the groups can only be edited in NTA.
Show answer and explanation ▾

Correct answer: A

IP address groups are synchronized in one direction, from IPAM to NTA. Any change made in IPAM is automatically reflected in NTA after a short delay.

Why the other options are wrong:

  • B. The synchronization does not run from NTA to IPAM.
  • C. The groups can be synchronized, so they do not exist only separately.
  • D. Groups imported from IPAM cannot be edited in NTA, only in IPAM.

Question 9

Which tool is used to establish flow alerts?

  • A. create alert flows
  • B. create a flow alert panel
  • C. flow alert wizard
  • D. manage flow alert panel
Show answer and explanation ▾

Correct answer: B

Flow alerts are configured in the Create a Flow Alert panel. The panel builds a standard platform alert from the flow conditions you choose, and it can open that alert in the general alert wizard before saving.

Why the other options are wrong:

  • A. Create alert flows is not the name of the tool used to establish flow alerts.
  • C. Flow alert wizard is not the name of the tool: flow alerts are set up in a panel, and the only wizard involved is the general alert wizard.
  • D. Manage flow alert panel is not the tool used to establish new flow alerts.

Question 10

Which two of the following requirements are needed to monitor an application on a server? (Choose two.)

  • A. Add application and ports using server as source and destination IP addresses.
  • B. Add the IP address of the server into an IP address group.
  • C. Click the monitor recommendation applications button.
  • D. Find the application to monitor in the list of available applications and enable it.
Show answer and explanation ▾

Correct answer: B, D

To monitor an application on a server, the server's IP address is placed in an IP address group, and the application is located in the list of available applications and enabled.

Why the other options are wrong:

  • A. Using the server as both source and destination address is not how an application is set up for monitoring.
  • C. A monitor recommendation applications button is not part of this setup.

Question 11

A network discovery profile for a network area completes with most devices discovered, except for a few SNMP enabled network devices. These undiscovered devices are verified to be operational and respond to SNMP queries.

What could be the cause?

  • A. device MIB is not in SolarWinds' MIB database
  • B. discovery timeout value is set too low
  • C. no SNMP pollers match the device
  • D. SNMP community strings in profile are invalid
Show answer and explanation ▾

Correct answer: C

When devices are up and answer SNMP queries but are still not brought in by discovery, the cause is that no SNMP poller matches those devices.

Why the other options are wrong:

  • A. A missing MIB entry does not stop a responding SNMP device from being discovered.
  • B. The devices respond to SNMP queries, so a timeout is not the cause.
  • D. The devices respond to SNMP queries, so the credentials are valid.

Question 12

Which option within the log and event monitoring section of node properties will enable log and event monitoring for syslog and SNMP traps?

  • A. default
  • B. disabled
  • C. informational
  • D. standard
Show answer and explanation ▾

Correct answer: A

The log and event monitoring setting has three options: Default, Enabled and Disabled. With Default, monitoring is enabled for the node on receipt of the first message, and this option applies to syslog and SNMP trap messages only.

Why the other options are wrong:

  • B. Disabled turns monitoring off for the node, and its log and event data is discarded.
  • C. Informational is a message severity, not an option of this setting.
  • D. Standard is not one of the options of this setting.

Question 13

Which two of the following troubleshooting steps can be performed when a node is "up" and the data cannot be found in SolarWinds' platform web console? (Choose two.)

  • A. Add a remote site node and make sure the firewall rules are configured to allow SNMP traffic.
  • B. Ping the device from the polling engine the device is assigned to using the command line.
  • C. Verify hardware health sensors on the device provide both status and values.
  • D. Wait ten minutes after a device is added to the console. Refresh the screen.
Show answer and explanation ▾

Correct answer: B, D

Pinging the device from its assigned polling engine confirms that the engine can reach it, and waiting about ten minutes after adding the device gives the first polling cycles time to populate the console.

Why the other options are wrong:

  • A. Adding a remote site node is not a step for finding data for a node that is already up.
  • C. Hardware health sensors are unrelated to missing node data in the console.

Question 14

Which SNMP version allows usernames and passwords?

  • A. version 1
  • B. version 2c
  • C. version 3
  • D. version 4
Show answer and explanation ▾

Correct answer: C

SNMP version 3 adds user-based security, with a username plus authentication and privacy passwords, instead of a plain text string shared by all users.

Why the other options are wrong:

  • A. Version 1 has no user-based authentication.
  • B. Version 2c has no user-based authentication.
  • D. Version 4 is not an SNMP version in use.

Question 15

Which three of the following are mandatory fields for the flow template schema? (Choose three.)

  • A. interface Rx
  • B. protocol
  • C. source address
  • D. source port
Show answer and explanation ▾

Correct answer: A, B, C

The mandatory fields of a flow template include the protocol, the source and destination addresses, and at least one interface field, which can be the ingress interface index (interface Rx) or the egress interface index.

Why the other options are wrong:

  • D. Source port is an optional field: when it is not in the template, a default value is stored.

Question 16

A Windows device is not showing statistics data when trying to poll with its native poller. It has been determined that several ports in the firewall are blocked.

Which polling method can be used to poll for the Windows device over a single port of communication?

  • A. agent
  • B. API
  • C. CLI
  • D. SNMP
Show answer and explanation ▾

Correct answer: A

The agent is software installed on the Windows device that sends its data to the platform over a single port, so it works where a firewall blocks the many ports native Windows polling needs.

Why the other options are wrong:

  • B. API polling is not the method for collecting Windows server statistics over one port.
  • C. CLI polling is used for network devices, not for Windows statistics.
  • D. SNMP is not the single-port replacement described for native Windows polling.

Question 17

An existing NetPath probe is examined, and it is noted that the thickness of connection lines is different on various routes between devices.

What does this indicate?

  • A. The probing interval for the probe is shorter on one path than on the other.
  • B. The thicker line indicates the more likely path of traffic from source to destination.
  • C. The thicker line is monitored in hybrid cloud observability (HCO) and contains other metrics.
  • D. Two probes with different probing intervals are monitoring the same path.
Show answer and explanation ▾

Correct answer: B

NetPath draws every route it finds between source and destination. A thicker line marks the route that traffic is more likely to take.

Why the other options are wrong:

  • A. A probe has one probing interval, so it does not differ between paths.
  • C. Line thickness does not show whether a segment is monitored.
  • D. Line thickness does not indicate a second probe on the same path.

Question 18

Which two of the following reasons should NetFlow data be collected on a company network? (Choose two.)

  • A. authorize user network access
  • B. diagnose slow network performance
  • C. identify applications causing congestion
  • D. report network link up / down instances
Show answer and explanation ▾

Correct answer: B, C

NetFlow records who is talking to whom and with which applications, so it is used to diagnose slow network performance and to identify the applications that cause congestion.

Why the other options are wrong:

  • A. NetFlow reports on traffic and does not authorize user access.
  • D. Link up and down events are reported by status polling and traps, not by flow data.

Question 19

Which three of the following technologies are supported to create device studio pollers? (Choose three.)

  • A. multi-CPU / memory
  • B. node details
  • C. single CPU / memory
  • D. VLAN details
Show answer and explanation ▾

Correct answer: A, B, C

Device Studio supports three technologies: CPU and memory for single processor systems, multi CPU and memory for multiprocessor systems, and node details.

Why the other options are wrong:

  • D. VLAN is a polling technology that cannot be used to create pollers in Device Studio.

Question 20

How are additional collection ports added?

  • A. replace existing port with new port in the NetFlow collector services widget
  • B. separate listed ports with a comma in the NetFlow collector services widget
  • C. stop SolarWinds' NetFlow service and separate listed ports with a comma in the NetFlow collector services widget
  • D. stop SolarWinds' NetFlow service and change the collection port in the NetFlow collector services widget
Show answer and explanation ▾

Correct answer: B

Additional collection ports are added in the NetFlow collector services widget by listing the ports separated with a comma.

Why the other options are wrong:

  • A. Replacing the existing port changes the port and does not add one.
  • C. Stopping the NetFlow service is not part of adding a collection port.
  • D. Stopping the service and changing the port does not add an additional port.

Question 21

The unclassified traffic in the web console has been identified as MSSQL traffic. It is known as an application mapping that hybrid cloud observability maps by default.

Which two of the following reasons explain why the traffic is showing as unclassified? (Choose two.)

  • A. A different port is being used.
  • B. A firewall is blocking the traffic.
  • C. The source or the destination port field is not present.
  • D. The version of MSSQL being used is not supported.
Show answer and explanation ▾

Correct answer: A, C

Applications are mapped by port. Traffic shows as unclassified when the application runs on a port other than the mapped one, or when the flow lacks the source or destination port field needed to match it.

Why the other options are wrong:

  • B. Blocked traffic would not appear in the flow data at all.
  • D. Application mapping depends on ports, not on the MSSQL version.

Question 22

Which task must be accomplished to monitor access lists within Cisco ASA?

  • A. Enable SNMP and CLI polling.
  • B. Enable SNMP and CLI polling and monitor with NCM.
  • C. Enable WMI and CLI polling.
  • D. Enable WMI and CLI polling and mentor with NCW.
Show answer and explanation ▾

Correct answer: B

Cisco ASA firewalls are polled with both SNMP and CLI, and access list details come from NCM, so the node must also be monitored with NCM.

Why the other options are wrong:

  • A. SNMP and CLI polling alone does not provide access list monitoring.
  • C. WMI is used for Windows systems, not for Cisco ASA firewalls.
  • D. WMI is used for Windows systems, not for Cisco ASA firewalls.

Question 23

Which two of the following actions can be taken to resolve duplicate flows? (Choose two.)

  • A. Enable the flow de-duplication feature.
  • B. Enable automatic addition of flow sources.
  • C. Ensure NetFlow is enabled for ingress interfaces.
  • D. Ensure NetFlow export is enabled on sub-interfaces.
Show answer and explanation ▾

Correct answer: A, C

Duplicate flows appear when the same traffic is exported more than once, for example when both ingress and egress export are applied on a device. Keeping NetFlow enabled on ingress interfaces only, together with flow de-duplication, means each conversation is counted once.

Why the other options are wrong:

  • B. Automatically adding flow sources does not remove duplicate flows.
  • D. Export enabled on subinterfaces in addition to their physical interface is a cause of duplicate flows, not a fix.

Question 24

Which two of the following requirements are needed to set up network devices and export NetFlow data? (Choose two.)

  • A. Each device can be optionally configured to export NetFlow data to SoarWinds' NTA.
  • B. Each device that exports NetFlow data to SolarWinds' NTA must be monitored in NCM.
  • C. Each device that exports NetFlow data to SolarWinds' NTA must be monitored in NPM.
  • D. The interface through which a device exports NetFlow data must be monitored in NPM.
Show answer and explanation ▾

Correct answer: C, D

Each device that exports NetFlow data to NTA must be monitored in NPM, and the specific interface through which the device exports that data must be monitored in NPM as well.

Why the other options are wrong:

  • A. Export is not optional: each device must be configured to export NetFlow data to NTA.
  • B. Monitoring in NCM is not a requirement for exporting NetFlow data.

Question 25

It is taking longer than normal for a single mission critical node to poll for data.

Where would the polling interval for the node be changed?

  • A. Node Details Summary > Edit Node > Polling
  • B. Node Details Summary > Resources > Memory
  • C. Settings > All Setting > Core Thresholds
  • D. Settings > All Settings > Polling Settings
Show answer and explanation ▾

Correct answer: A

The polling interval for one node is changed in that node's own properties: open the node details summary, choose Edit Node, and adjust the values in the polling section.

Why the other options are wrong:

  • B. The memory resource shows statistics and has no polling interval setting.
  • C. Core thresholds set warning and critical levels, not polling intervals.
  • D. Polling settings change the defaults for all nodes, not for a single node.

Question 26

Which two of the following data sources can be used for polling devices in device studio? (Choose two.)

  • A. calculated result from transformation of polled values
  • B. night and day standard deviation of calculated value
  • C. polled value by a device on an object ID (OID)
  • D. predicted value from OID baseline
Show answer and explanation ▾

Correct answer: A, C

A Device Studio poller gets its data either as a value polled from the device on an OID or as a calculated result from a transformation of polled values.

Why the other options are wrong:

  • B. Standard deviation of a calculated value is not a Device Studio data source.
  • D. A predicted value from a baseline is not a Device Studio data source.

Question 27

Which application classification system is used with deep packet inspection technologies to provide better visibility into network traffic and is a mechanism used by certain Cisco routers / switches to recognize dataflow by inspecting some of the packets sent?

  • A. autonomous systems
  • B. CBQoS drops
  • C. flow navigator
  • D. NBAR2 applications
Show answer and explanation ▾

Correct answer: D

NBAR2 is the Cisco classification mechanism that inspects packets to recognize applications, giving deeper visibility into network traffic than port-based mapping.

Why the other options are wrong:

  • A. Autonomous systems group networks under one routing policy and do not classify applications.
  • B. CBQoS drops report traffic dropped by quality of service policies.
  • C. Flow navigator builds filtered traffic views and is not a classification system.

Question 28

From which two of the following locations can the status of the flow collector service be checked? (Choose two.)

  • A. flow and CBQoS sources
  • B. NetFlow collector services
  • C. NetFlow settings
  • D. top XX receivers
Show answer and explanation ▾

Correct answer: B, C

The status of the flow collector service is shown in the NetFlow collector services widget and can also be checked from NetFlow settings.

Why the other options are wrong:

  • A. Flow and CBQoS sources lists the devices and interfaces that send flows, not the service status.
  • D. Top XX receivers is a traffic chart and does not show service status.

Question 29

In live mode, how frequently is log viewer data automatically refreshed?

  • A. 1 second
  • B. 10 seconds
  • C. 1 minute
  • D. 10 minutes
Show answer and explanation ▾

Correct answer: B

In live mode, log viewer data is automatically refreshed every 10 seconds, so new entries appear without reloading the page by hand.

Why the other options are wrong:

  • A. Live mode does not refresh every second.
  • C. Live mode refreshes more often than once a minute.
  • D. Live mode refreshes far more often than every 10 minutes.

Question 30

A device studio poller is being built for a router statistic. It is determined that its object ID (OID) does not exist in SolarWinds' MIB database.

What is the best workaround for this situation?

  • A. consult vendor and add OID to the database
  • B. download database from customer portal
  • C. select manually define object identifier and specify SNMP
  • D. select SNMP and ICMP as the router's polling method
Show answer and explanation ▾

Correct answer: C

When an OID is not in the MIB database, Device Studio lets you select the option to manually define the object identifier and enter the OID yourself.

Why the other options are wrong:

  • A. Consulting the vendor to add the OID to the database is not the workaround Device Studio provides.
  • B. Downloading the database does not help when the OID is not in it.
  • D. Changing the polling method to SNMP and ICMP does not supply the missing OID.

Question 31

In setting up a storage and search retention period for log analyzer, what is the default retention period?

  • A. 24 hours
  • B. 7 days
  • C. 21 days
  • D. 31 days
Show answer and explanation ▾

Correct answer: B

The default storage and search retention period is seven days. It can be adjusted to anywhere from one day to one year.

Why the other options are wrong:

  • A. 24 hours is the minimum that can be set, not the default.
  • C. 21 days is not the default retention period.
  • D. 31 days is not the default retention period.

Question 32

What is the most efficient way to create a custom NetFlow view to access at a later time?

  • A. Create the view from charting and graphing in NetFlow settings.
  • B. Create the view from flow navigator and click the submit button.
  • C. Create the view from flow navigator and save to the menu bar.
  • D. Create the view from NetFlow settings and save to menu bar.
Show answer and explanation ▾

Correct answer: C

Flow navigator builds a custom filtered traffic view, and saving that view to the menu bar keeps it available for later access.

Why the other options are wrong:

  • A. Charting and graphing settings set chart defaults and do not create custom views.
  • B. Submitting the view applies it once and does not keep it for later.
  • D. Custom views are built in flow navigator, not in NetFlow settings.

Question 33

When attempting to add universal device poller (UDP) results to a new chart widget, none of the custom poller results are displayed. If the web console switches to another view, the data appears in the chart.

What is the most likely resolution?

  • A. user does not have correct permissions to view the data
  • B. unassign and reassign custom poller in UDP application
  • C. UDP application under web display, chart box must be checked for each view to be used
  • D. UDP application, click transform result to convert them into a format viewable in a chart
Show answer and explanation ▾

Correct answer: C

Each Universal Device Poller is enabled per web console view. Under web display in the application, the chart box must be checked for every view where the poller results should appear.

Why the other options are wrong:

  • A. The data appears in another view, so permissions are not the problem.
  • B. The poller already collects data, so reassigning it does not help.
  • D. Transform results combine or convert values and do not control which views show a chart.

Question 34

In customizing the flow direction of SolarWinds' platform views, which statement is true?

  • A. Both ingress and egress views are available for the current session only.
  • B. Both ingress and egress views are available for the next two sessions.
  • C. Both ingress and egress views are available for 24 hours.
  • D. Both ingress and egress views are available for 48 hours.
Show answer and explanation ▾

Correct answer: A

Flow direction changes made on a view are limited to the current session. Once you leave the view, all widgets show the default flow direction settings again.

Why the other options are wrong:

  • B. The change does not carry over to later sessions.
  • C. The change is not kept for 24 hours.
  • D. The change is not kept for 48 hours.

Question 35

How is an object ID (OID) verified as included in SolarWinds' MIB database and polled on a device?

  • A. add routers to the additional polling engine
  • B. go to manage pollers and find OID
  • C. run SNMPwalk on the device with the OID
  • D. verify the OID using the MIB browser
Show answer and explanation ▾

Correct answer: D

The MIB browser searches the MIB database for an OID and can test it against a device, which confirms both that the OID is in the database and that the device returns a value.

Why the other options are wrong:

  • A. Adding routers to another polling engine does not verify an OID.
  • B. Manage pollers lists existing pollers and is not the place to verify an OID.
  • C. This does not show whether the OID is included in the MIB database.

Question 36

Which three of the following data points does NetFlow use to confirm traffic is in the same flow? (Choose three.)

  • A. interface name
  • B. IP address
  • C. L3 protocol
  • D. port number
Show answer and explanation ▾

Correct answer: B, C, D

Packets belong to the same flow when they share the same identifying fields, which include the IP addresses, the Layer 3 protocol and the port numbers.

Why the other options are wrong:

  • A. The interface name is not one of the fields used to match packets to a flow.

Question 37

Which two of the following locations can peak and average calculations be generated in network capacity planning? (Choose two.)

  • A. global
  • B. local
  • C. memory usage on nodes
  • D. node threshold settings
Show answer and explanation ▾

Correct answer: A, B

Capacity forecasts can be based on peak or average calculations, and that choice can be made globally for all objects or locally for an individual object.

Why the other options are wrong:

  • C. Memory usage on nodes is a metric that is forecast, not a place where the calculation is chosen.
  • D. Node threshold settings are not where peak and average calculations are generated.

Question 38

Which custom filter allows a user to view specific statistics about an entire network and its devices without having to navigate through the web console by single-device views?

  • A. flow alert
  • B. flow navigator
  • C. NBAR2
  • D. top 10 applications
Show answer and explanation ▾

Correct answer: B

Flow navigator creates custom filtered views of traffic across the whole network, so specific statistics can be seen without opening single-device views one at a time.

Why the other options are wrong:

  • A. A flow alert notifies on traffic conditions and is not a custom filter view.
  • C. NBAR2 classifies applications and is not a filter tool.
  • D. Top 10 applications is a fixed chart, not a custom filter.

Question 39

Upon examining bandwidth utilization, it is confirmed that the total utilization and flow numbers do not match.

What is the likely cause?

  • A. a firewall is blocking the data flow configuration
  • B. flows do not contain all traffic in bandwidth numbers
  • C. receiving both IPv4 and IPv6 flows and not all are counted in total bandwidth
  • D. SNMP bandwidth numbers for the interface need to be adjusted in the console
Show answer and explanation ▾

Correct answer: B

Interface utilization counts every bit crossing the interface, while flow records cover only the traffic the device exports as flows. Because flows do not contain all of that traffic, the two totals differ.

Why the other options are wrong:

  • A. A firewall block would stop flow data from arriving and would not explain a partial mismatch.
  • C. Receiving IPv4 and IPv6 flows is not the reason the totals differ.
  • D. SNMP bandwidth numbers are polled from the device and are not adjusted to match flows.

Question 40

Which statement is true regarding device studio pollers?

  • A. Device studio pollers can poll object IDs (OIDs) that are not found in SolarWinds' MIB database.
  • B. Device studio pollers can poll OIDs that are not found in the target device's MIB database.
  • C. Each device studio poller package can only poll single OID.
  • D. Each result from a device studio poller is displayed in a widget.
Show answer and explanation ▾

Correct answer: A

Device Studio lets you manually define an object identifier, so its pollers can poll OIDs that are not in the MIB database.

Why the other options are wrong:

  • B. A device cannot return a value for an OID it does not support.
  • C. A Device Studio poller can contain more than one OID.
  • D. Not every result from a Device Studio poller is displayed in a widget.

Question 41

A node is not able to calculate CPU load threshold.

Where in SolarWinds' platform can a user confirm CPU load is included in the node status calculation?

  • A. core thresholds
  • B. custom poller thresholds
  • C. node status contributors
  • D. polling settings
Show answer and explanation ▾

Correct answer: C

Node status contributors lists the metrics that feed the node status calculation, so it is where you confirm that CPU load is included.

Why the other options are wrong:

  • A. Core thresholds set the warning and critical levels, not which metrics contribute to status.
  • B. Custom poller thresholds apply to custom pollers, not to CPU load in node status.
  • D. Polling settings control intervals and retention, not status contributors.

Question 42

Which three of the following steps should be taken to troubleshoot a 'test failed' result for SNMP nodes in hybrid cloud observability? (Choose three.)

  • A. Add remote site node and confirm firewall rules are configured to allow SNMP traffic.
  • B. Confirm the use of SNMPv2 with authentication keys.
  • C. Verify the node can be pinged from the application server.
  • D. Verify the SNMP service on the node has been restarted after changing the community string.
Show answer and explanation ▾

Correct answer: A, C, D

A failed SNMP test usually points to reachability or to the SNMP service. Confirm that firewall rules allow SNMP traffic for the remote site node, that the node can be pinged from the application server, and that the SNMP service was restarted after its string was changed.

Why the other options are wrong:

  • B. SNMPv2 does not use authentication in that way, so this is not a troubleshooting step.

Question 43

If a NetFlow collector service is showing a "down" status, which two of the following steps are possible troubleshooting options? (Choose two.)

  • A. Confirm the database connection is up and server has free resources.
  • B. Delete and re-add NetFlow collector service.
  • C. Start or restart SolarWinds' collector service.
  • D. Start or restart SolarWinds' NetFlow service from Orion service manager.
Show answer and explanation ▾

Correct answer: A, D

A collector service shown as down is checked by confirming that the database connection is up and the server has free resources, and by starting or restarting the NetFlow service from the service manager.

Why the other options are wrong:

  • B. Deleting and re-adding the collector service is not a troubleshooting step for a down status.
  • C. The service to start or restart is the NetFlow service, from the service manager.

Question 44

Which two of the following services can be monitored in network insight with network health, performance monitor, and NCM features installed in hybrid cloud observability? (Choose two.)

  • A. access lists
  • B. global protect VPN
  • C. high availability details
  • D. policy details
Show answer and explanation ▾

Correct answer: A, C

With the network monitoring and NCM features installed, Network Insight for firewalls shows access lists and high availability details for the device.

Why the other options are wrong:

  • B. GlobalProtect VPN is not one of the two services listed for this feature combination.
  • D. Policy details is not one of the two services listed for this feature combination.

Question 45

In device studio, the test node being built for a new custom poller is returning four usage values for the CPU (one for each CPU core). If the goal is to have one value for the entire CPU, how can that be accomplished?

  • A. create a new calculated value to average the four individual values
  • B. device studio would not be the correct tool to use this situation
  • C. there is not an object ID (OID) for CPU usage, nothing can be done
  • D. values can be combined after he poller is create in pole settings
Show answer and explanation ▾

Correct answer: A

Device Studio can add a calculated value built from polled values. Averaging the four per-core values produces one usage figure for the whole CPU.

Why the other options are wrong:

  • B. Device Studio supports this through calculated values, so it is the correct tool.
  • C. The device is already returning CPU usage values, so an OID exists.
  • D. The values are combined while building the poller, not afterward in other settings.

Question 46

It is noted that the hardware health monitoring for a Cisco switch is generating false positives. It is verified that the alerted hardware issues are not occurring.

What is causing the issue?

  • A. Hardware sensors were incorrectly assigned to another switch.
  • B. MIB on the device is not the preferred MIB that is being polled.
  • C. Modify the widget thresholds to filter out the false positives.
  • D. Restart SNMP on the device to refresh the hardware statistics.
Show answer and explanation ▾

Correct answer: B

Cisco devices can report hardware health through more than one MIB. If the MIB being polled is not the preferred one for the device, the sensor readings can be wrong and produce false alerts.

Why the other options are wrong:

  • A. Hardware sensors are polled from each device and are not assigned across switches.
  • C. This is an action, not a cause, and it would only hide the false readings.
  • D. This is an action, not a cause of the false positives.

Question 47

A brocade G620 switch is not able to poll for hardware health statistics after adding a node using SNMPv3 as the polling method.

Why are hardware health statistics not showing in the node details summary page?

  • A. device does not support SNMPv3
  • B. MIB database needs to be updated
  • C. switch is not supported for collection
  • D. server configuration box is not checked
Show answer and explanation ▾

Correct answer: C

Hardware health is collected only for device models the platform supports. A switch that is not supported for hardware health collection shows no hardware health statistics, whichever SNMP version is used.

Why the other options are wrong:

  • A. The node was added with SNMPv3, so the device supports it.
  • B. Updating the MIB database does not add hardware health support for a device.
  • D. A server configuration box is not what controls hardware health collection.

Question 48

Which custom poller can display the poller results as a chart, gauge, or table?

  • A. device studio poller
  • B. hardware health
  • C. network insight
  • D. universal device poller (UnDP)
Show answer and explanation ▾

Correct answer: D

When a Universal Device Poller is created, you select the web console views that can display the poller as a chart, gauge or table.

Why the other options are wrong:

  • A. Device Studio poller results feed standard resources such as CPU and memory and node details.
  • B. Hardware health is a built-in sensor feature, not a custom poller.
  • C. Network Insight is a monitoring feature for specific device types, not a custom poller.

Question 49

On which two of the following occasions do custom pollers need to be created? (Choose two.)

  • A. monitor equipment that does not support WHI
  • B. monitor special equipment
  • C. monitor specific metric that is not out-of-the-box
  • D. monitor unsupported object ID (OID)
Show answer and explanation ▾

Correct answer: C, D

Custom pollers are created when a needed metric is not collected out of the box, or when an OID is not supported by the built-in pollers.

Why the other options are wrong:

  • A. This is not a stated reason for creating a custom poller.
  • B. Special equipment alone is not a reason; the need is an unsupported metric or OID.

Question 50

Flow data is not generating from a device in the web console. Wireshark was used to confirm the flows are being sent from the device to the poller and not blocked by the firewall.

Why is the data not showing in the web console?

  • A. device is not monitored by hybrid cloud observability (HCO) features
  • B. device is using IPv6 and HCO only supports IPv4
  • C. missing source address field in flow configurations
  • D. flow monitoring was not enabled as device type in web console settings
Show answer and explanation ▾

Correct answer: A

Flows are accepted only from devices and interfaces that are already monitored by the platform. Flows arriving from a device that is not monitored are not shown in the web console.

Why the other options are wrong:

  • B. IPv6 use is not the reason the flows are missing.
  • C. A missing source address field is not the cause in this scenario.
  • D. Flow monitoring is not enabled as a device type in web console settings.

Question 51

Which additional polling method is needed after adding an F5 load balancing node for SNMP monitoring?

  • A. API
  • B. CLI
  • C. iControl
  • D. WMI
Show answer and explanation ▾

Correct answer: C

F5 BIG-IP devices are polled with SNMP and, in addition, with the F5 iControl API, which supplies health monitor details and allows actions on pool members.

Why the other options are wrong:

  • A. The additional method is named iControl specifically, not a generic API.
  • B. CLI is not the additional polling method for F5 nodes.
  • D. WMI is used for Windows systems, not for F5 devices.

Question 52

Some of the flows received are mapping to an IP address that does not match any of the nodes being monitored. It has been verified that all flow sources are also being monitored by NPM and SNMP polling. The known source nodes for these flows have the correct IP address.

What could be causing this issue?

  • A. flows are coming from a non-primary address and the selling to match the node by another IP is turned off
  • B. flows are IPv6 and the network monitoring does not recognize that version
  • C. IP address for the node is incorrect in SNMP polling but correct in the flows
  • D. source machine field in the flows is not configured and the setting to match the node by another IP is turned off
Show answer and explanation ▾

Correct answer: A

A device can send flows from an address other than its primary polling address. If the setting that matches a node by another of its IP addresses is turned off, those flows cannot be tied to the monitored node.

Why the other options are wrong:

  • B. IPv6 use is not the cause of the unmatched address.
  • C. The scenario states the source nodes have the correct IP address.
  • D. A source machine field in the flows is not what determines the match.

Question 53

Which NetFlow component can be applied to an interface to track IPv4 traffic?

  • A. flow exporter
  • B. flow monitor
  • C. flow record
  • D. flow sampler
Show answer and explanation ▾

Correct answer: B

In Flexible NetFlow, the flow monitor is the component applied to an interface. It ties together the flow record and the flow exporter and tracks the traffic, such as IPv4, on that interface.

Why the other options are wrong:

  • A. A flow exporter defines where flow data is sent and is attached to a monitor, not to an interface.
  • C. A flow record defines the fields to collect and is attached to a monitor, not to an interface.
  • D. A flow sampler sets the sampling rate and does not track traffic by itself.

Question 54

On which two of the following port does log analyzer listen for TCP syslog messages? (Choose two.)

  • A. 162
  • B. 514
  • C. 1468
  • D. 6514
Show answer and explanation ▾

Correct answer: C, D

Log Analyzer listens for TCP syslog messages on ports 1468 and 6514. UDP messages are received on port 514.

Why the other options are wrong:

  • A. Port 162 is used for SNMP traps.
  • B. Port 514 is where UDP syslog messages are received.

Question 55

A poller is to be built that will add two values together to show a single value in the web console using the universal device poller (UDP) tool.

How would this be accomplished?

  • A. add both object IDs (OIDs) to the poller and combine values in a single value for the web console
  • B. build a poller for each OID then use transform results to combine values from the two pollers
  • C. UDP tool does not support more than one OID per poller, another OID is needed
  • D. UDP tool does not support more than one OID per poller, another tool is needed
Show answer and explanation ▾

Correct answer: B

In the Universal Device Poller, each value is collected by its own poller. The transform results feature then applies a formula, such as addition, to combine the two pollers into one value.

Why the other options are wrong:

  • A. A single poller does not combine two OIDs into one value.
  • C. A second OID is already available, and the tool can combine the two pollers.
  • D. No other tool is needed, because transform results combine the pollers.

Question 56

Which two of the following locations can be checked for network hardware health functionality? (Choose two.)

  • A. device view
  • B. node properties
  • C. list resources
  • D. manage sensors
Show answer and explanation ▾

Correct answer: B, C

Hardware health polling for a node can be checked in the node properties and in list resources, where the hardware health sensors option shows whether collection is enabled.

Why the other options are wrong:

  • A. Device view is not one of the two places used to check hardware health functionality.
  • D. Manage sensors is not one of the two locations identified for this check.

Question 57

Which three of the following actions are native log entry actions? (Choose three.)

  • A. add a tag to the log entry
  • B. continue rule processing but do not save
  • C. halt further rule processing for the log entry
  • D. send an email notification
Show answer and explanation ▾

Correct answer: A, B, C

Native rule actions include tagging the entry, flagging it for discard so it is not saved while later rule actions still apply, and stopping further rule processing for that log entry.

Why the other options are wrong:

  • D. Sending an email notification is not one of the native log entry actions.

Question 58

What is required to submit an MIB database update request to SolarWinds?

  • A. polling interval to monitor the metric
  • B. SNMP or MIB walk from the device
  • C. specific object ID (OID) for polling
  • D. type of widget to populate data
Show answer and explanation ▾

Correct answer: C

A MIB database update request needs the specific OID that is to be polled, so the right definition can be added to the database.

Why the other options are wrong:

  • A. A polling interval is a poller setting and is not needed for the request.
  • B. This is not the required item for the request.
  • D. The widget type is a display choice and is not needed for the request.

Question 59

What can be done to show the description of an object ID (OID)?

  • A. Contact vendor to obtain the latest SNMPwalk.
  • B. Download the latest OID.cfg from customer portal.
  • C. Perform an SNMPwalk on the target device.
  • D. Update the MIB database via SolarWinds support.
Show answer and explanation ▾

Correct answer: C

Performing an SNMP walk on the target device lists the OIDs the device returns along with their details, which shows the description of an OID.

Why the other options are wrong:

  • A. Contacting the vendor is not the step used to show an OID description.
  • B. Downloading a configuration file from the customer portal is not the step used here.
  • D. A database update through support is not the step used to show the description.

Question 60

What is the default amount of historical data needed for calculating capacity forecast?

  • A. 1 to 30 days
  • B. 1 to 90 days
  • C. 7 to 30 days
  • D. 7 to 180 days
Show answer and explanation ▾

Correct answer: D

By default, capacity forecasting requires at least 7 days of historical data, and the longest period taken into account for the calculation is 180 days. The more history is available up to 180 days, the more precise the forecast.

Why the other options are wrong:

  • A. One day of history is below the default minimum of 7 days, and 30 days is not the default upper limit.
  • B. One day of history is below the default minimum of 7 days, and 90 days is not the default upper limit.
  • C. The lower limit of 7 days fits, but 30 days is not the default longest period used for the calculation.

Question 61

Which two of the following standards does hybrid cloud observability use to capture flow data and CBQoS data? (Choose two.)

  • A. IPFix
  • B. J-Flow
  • C. NetFlow
  • D. SNMP
Show answer and explanation ▾

Correct answer: A, C

Flow analysis in the platform is built on flow export standards: devices export traffic records as NetFlow or as IPFIX, the IETF standard that grew out of NetFlow version 9, and the collector receives and analyzes those records.

Why the other options are wrong:

  • B. J-Flow is a vendor implementation of flow export, not one of the two standards the question asks for.
  • D. SNMP is a management and polling protocol, not a flow export standard.

Question 62

A "no data" message is displayed in NetFlow charts.

How can this be resolved?

  • A. Confirm account has viewing permissions.
  • B. Refresh the current window.
  • C. Restart collector service.
  • D. Shorten the time for view and resource.
Show answer and explanation ▾

Correct answer: D

When the flow data for the selected period takes more than an hour to process, the query times out and the charts show the "no data" message. Defining a shorter time period for both the view and the resource lets the query finish and the charts fill.

Why the other options are wrong:

  • A. Viewing permissions are not what produces the "no data" message in the charts.
  • B. Refreshing the window runs the same long query again, so the message returns.
  • C. Restarting the collector service does not shorten the query that is timing out.

Question 63

What can be done to display the average CPU utilization of a node in a web console widget, if the device studio poller returns a table of multi-core CPU utilizations?

  • A. Configure the web console widget to calculate the average of the returned table values.
  • B. Contact the device vendor to provide an SNMP object ID (OID) for the average CPU utilization statistic.
  • C. Display the returned table of values in the web console widget and manually calculate the average.
  • D. Select the add calculated value option and use the average function for returned values.
Show answer and explanation ▾

Correct answer: D

When a device returns CPU utilization as a table with one value per core, Device Studio can transform it with Add Calculated Value. Choosing the Average function turns the table of values into a single value that the poller reports for the node.

Why the other options are wrong:

  • A. The averaging is defined in the Device Studio poller, not in the web console widget.
  • B. No extra OID from the vendor is needed, because the poller can calculate the average from the returned table.
  • C. Calculating the average by hand is not needed, because the poller can do it with a calculated value.

That was 63 of 164.

The full SolarWinds Observability Self-Hosted Network Monitoring pack has all 164 questions, each with the answer, the explanation and why the other options are wrong, plus a questions-only copy for timed runs. $39.00 USD, paid once, with free monthly updates and a pass-or-your-money-back guarantee.

Get the full pack

Not ready yet? Get the first 63 free as one PDF by email. Get the Half Pack →

About the Observability Self-Hosted Network Monitoring exam

These 63 SolarWinds Observability Self-Hosted Network Monitoring questions are free here, and as a free PDF by email.

They are drawn from the same bank as the full Observability Self-Hosted Network Monitoring pack, which has 164 questions in total.

Back to blog