NetApp NS0-175 Practice Questions with Explanations
Free NetApp NS0-175 practice questions. 21 of them, each with the correct answer, a full explanation, and the reason every other option is wrong.
NS0-175 practice questions
Question 1
You are sizing a FlexPod Datacenter solution for multitenancy use.
What are two important platform scaling considerations in this scenario? (Choose two.)
- A. maximum NetApp ONTAP cluster limits
- B. maximum NetApp ONTAP storage VM limits
- C. maximum Cisco vPC interfaces between Fabric Interconnects
- D. maximum Cisco L1, L2 interfaces between Fabric Interconnects
Show answer and explanation ▾
Correct answer: A, D
A multitenant FlexPod grows until it reaches platform maximums. On the storage side the ceiling is the set of ONTAP cluster limits, and on the compute side the Fabric Interconnect pair depends on its dedicated L1 and L2 cluster links, which are fixed in number.
Why the other options are wrong:
- B. Storage VMs are logical tenants created inside a cluster, so the cluster limits are the platform ceiling to size against.
- C. vPC interfaces are configured on the Cisco Nexus switches, not between the Fabric Interconnects.
Question 2
You are developing a FlexPod solution with a MetroCluster IP as the storage solution.
In this scenario, which two components are supported? (Choose two.)
- A. NetApp AFF C190
- B. Cisco Nexus 3524-X/XL
- C. Cisco Nexus 3232C
- D. NetApp AFF A400
Show answer and explanation ▾
Correct answer: C, D
The Nexus 3232C switch and the NetApp AFF A400 controller are both supported for a FlexPod with MetroCluster IP.
Why the other options are wrong:
- A. The AFF C190 is not a supported component in this MetroCluster IP design.
- B. The Nexus 3524-X/XL is not a supported switch in this design.
Question 3
You are asked to evaluate SaaS-based monitoring solutions for your FlexPod environment. Other than being SaaS-delivered, selection criteria include full lifecycle management, environment automation, and the ability to monitor third-party storage that is salted for retirement.
In this scenario, which product satisfies the requirements?
- A. NetApp Cloud Insights
- B. NetApp OnCommand Insight
- C. Cisco UCS Manager
- D. Cisco Intersight
Show answer and explanation ▾
Correct answer: A
Cloud Insights is NetApp's SaaS monitoring service and it can monitor third-party storage, which matches all the criteria.
Why the other options are wrong:
- B. OnCommand Insight is not SaaS delivered.
- C. UCS Manager is embedded management for UCS and is not a SaaS monitoring service.
- D. Intersight is SaaS but does not meet the third-party storage monitoring requirement in this scenario.
Question 4
A customer wants to use a Cisco Nexus 93180YC-FX switch to support the FC protocol for booting from SAN without having to deploy additional Cisco 900 Series MDS switches in their FlexPod Datacenter configuration.
In this scenario, what is required for this solution?
- A. The customer must enable the FC license on the 93180YC-FX switch
- B. The customer must deploy the 93180YC-FX switch as part of a Cisco ACI fabric
- C. The customer must directly connect the NetApp AFF system to the Cisco UCS Fabric Interconnects
- D. The customer must add an expansion FC module to the 93180YC-FX switch
Show answer and explanation ▾
Correct answer: C
Without MDS switches, FC boot from SAN is delivered by cabling the NetApp AFF FC target ports straight to the Cisco UCS Fabric Interconnects, which then switch the FC traffic and handle the zoning themselves.
Why the other options are wrong:
- A. An FC license on the Nexus switch is not what this direct-attached design requires.
- B. Cisco ACI is not needed to boot from SAN over FC.
- D. The 93180YC-FX is a fixed-configuration switch and takes no expansion FC module.
Question 5
You are designing a multi-site FlexPod Datacenter solution for a customer using MetroCluster over IP. The design should include a single set of compliant switches for the environment.
Which two features are required to satisfy this requirement? (Choose two.)
- A. support for Fibre Channel ports
- B. support for an MTU size of 9216
- C. support for unified switch ports
- D. support for QoS
Show answer and explanation ▾
Correct answer: B, D
A shared switch set for MetroCluster IP needs support for an MTU size of 9216 and for QoS.
Why the other options are wrong:
- A. Fibre Channel ports are not required for MetroCluster IP.
- C. Unified ports are not required for MetroCluster IP.
Question 6
You are sizing a FlexPod Virtual Desktop solution for a customer with 500 virtual desktops in a shared Remote Desktop Services (RDS) topology.
In this scenario, which Cisco best practice should you use?
- A. You should avoid placing more than 20 users per physical host
- B. You should avoid over-committing physical CPU resources for virtual machines
- C. You should avoid changing the virtual host disk queue depth
- D. You should avoid multiple vCPUs per individual virtual machine
Show answer and explanation ▾
Correct answer: B
In a shared RDS design many user sessions run on each server virtual machine, so CPU contention affects every session on it. Cisco guidance is to avoid over-committing physical CPU cores to the virtual machines that host the sessions.
Why the other options are wrong:
- A. A fixed cap of 20 users per physical host is not the Cisco sizing guidance for shared RDS.
- C. Disk queue depth is not the sizing best practice for this RDS workload.
- D. RDS server virtual machines are sized with multiple vCPUs, so avoiding them is not the guidance.
Question 7
You have a FlexPod solution that consists of a NetApp AFF A800 storage system, a Cisco MDS 9148S switch, and a Cisco UCS 6232 Fabric Interconnect. You want to upgrade NetApp ONTAP software on the AFF A800 to take advantage of a new feature.
In this scenario, which three tools would enable you to verify if the upgrade would be performed safely? (Choose three.)
- A. NetApp Interoperability Matrix Tool
- B. Cisco Intersight
- C. Cisco Data Center Network Manager
- D. Cisco UCS Hardware and Software Compatibility List
- E. NetApp Active IQ Upgrade Advisor
Show answer and explanation ▾
Correct answer: A, D, E
The NetApp Interoperability Matrix Tool confirms the new ONTAP release is supported with the rest of the stack, the Cisco UCS Hardware and Software Compatibility List confirms the Cisco side, and Active IQ Upgrade Advisor builds an upgrade plan that flags risks for the specific system.
Why the other options are wrong:
- B. Cisco Intersight is a management platform, not the tool used here to validate an ONTAP upgrade.
- C. Cisco Data Center Network Manager manages the network and SAN fabric and does not validate upgrade compatibility.
Question 8
You are designing a new FlexPod solution to use with VMware vSphere by using NFS datastores and want to ensure maximum availability by using a vPC.
In this scenario, on which Cisco component would you configure vPC interfaces?
- A. Cisco UCS Fabric Interconnect
- B. Cisco MDS switches
- C. Cisco Nexus switches
- D. UCS B-Series blade server
Show answer and explanation ▾
Correct answer: C
A virtual port channel is a Cisco Nexus feature that lets a device connect to two Nexus switches as if they were one. In FlexPod the vPCs are configured on the Nexus pair, facing the Fabric Interconnects and the NetApp controllers that carry the NFS traffic.
Why the other options are wrong:
- A. Fabric Interconnects connect to the Nexus pair with port channels but do not run vPC themselves.
- B. MDS switches carry Fibre Channel and do not provide vPC.
- D. A blade server does not configure vPC interfaces.
Question 9
What are three requirements for all FlexPod Datacenter solutions? (Choose three.)
- A. two NetApp storage controllers in a high-availability (HA) pair configuration
- B. a separate 100 Mbps Ethernet/1 Gbps Ethernet out-of-band management network
- C. a pair of Fabric Extenders in a redundant configuration
- D. two Cisco UCS 6200, 6300, or 6400 Series Fabric Interconnects in a redundant configuration
- E. redundant boot-from-SAN LUN paths
Show answer and explanation ▾
Correct answer: C, D, E
FlexPod Datacenter designs remove single points of failure in the compute and boot path: a pair of Fabric Extenders in a redundant configuration, two Cisco UCS 6200, 6300, or 6400 Series Fabric Interconnects in a redundant configuration, and redundant boot-from-SAN LUN paths so one failure cannot stop a host from booting.
Why the other options are wrong:
- A. The storage controller pairing is not one of the three compute and boot path requirements identified here.
- B. A separate out-of-band management network is not one of the three compute and boot path requirements identified here.
Question 10
A customer wants to deploy a FlexPod Datacenter solution in a limited amount of rack space. After planning for the networking and storage devices required for the deployment, they realize they have six rack units of space remaining. They need to install as many servers as possible in this available rack space.
In this scenario, which solution allows them to accomplish their objective?
- A. three Cisco UCS C4200 rack servers
- B. four Cisco UCS B480 M blade servers
- C. six Cisco UCS C220 M5 rack servers
- D. eight Cisco UCS B200 M5 blade servers
Show answer and explanation ▾
Correct answer: D
A Cisco UCS 5108 blade chassis is six rack units high and holds eight half-width blades such as the B200 M5, which gives the highest server count of the choices in the remaining space.
Why the other options are wrong:
- A. This option provides three rack servers, fewer than the eight blade servers.
- B. The B480 is a full-width blade, so the chassis holds only four of them.
- C. Six one rack unit C220 M5 servers fill the space with fewer servers than the blade chassis.
Question 11
A customer is verifying that they have separation on their FC switch fabric to protect their FlexPod solution from their other storage devices.
Which two technologies enable the customer to accomplish this task? (Choose two.)
- A. WWPN zoning
- B. VASN
- C. IQN igroup
- D. VLAN
Show answer and explanation ▾
Correct answer: A, B
Zoning by WWPN controls which initiators can reach which targets, and virtual SANs split one physical FC switch into isolated logical fabrics. Together they keep the FlexPod storage traffic apart from other storage devices on the same switches.
Why the other options are wrong:
- C. An IQN igroup is an iSCSI LUN masking object on the storage system, not a fabric separation feature.
- D. A VLAN segments Ethernet traffic, not a Fibre Channel fabric.
Question 12
A customer is deploying a FlexPod Datacenter and planning to boot from SAN each their UCS blades using the Fibre Channel Protocol.
In this scenario, which three actions would accomplish their objective? (Choose three.)
- A. Use only a pair of Cisco Nexus 9318YC-FX switches
- B. Create an igroup on the NetApp ONTAP storage system with the appropriate IQNs
- C. Use only a pair of Cisco Nexus 9336C-FX2 switches
- D. Use a pair of Cisco MDS 9148T and a fair of Cisco 9336C-FX2 switches together
- E. Create an igroup on the NetApp ONTAP storage system with the appropriate WWPNs
Show answer and explanation ▾
Correct answer: A, D, E
FC boot from SAN needs FC-capable switching and LUN masking by WWPN. The YC-FX Nexus pair can switch FC by itself, or MDS 9148T switches can carry FC next to Nexus 9336C-FX2 switches for Ethernet, and the ONTAP igroup must list the host WWPNs.
Why the other options are wrong:
- B. IQNs identify iSCSI initiators, not Fibre Channel initiators.
- C. A pair of Nexus 9336C-FX2 switches used alone does not provide the FC switching this boot design needs.
Question 13
A customer is unhappy with their current data center infrastructure. They want to purchase a FlexPod system to replace it. The customer asks you to help them understand the benefits of Solution Support to determine which support model would suit them best.
In this scenario, which three statements are correct? (Choose three.)
- A. You have a single point of contact for all cases
- B. Solution Support is a lower-cost support option
- C. There is no need to diagnose the problem before you call support
- D. Customers do not need to open tickets; all issues are automatically reported
- E. Issues are solved by solution experts
Show answer and explanation ▾
Correct answer: A, B, E
Solution Support gives the customer a single point of contact for every case across the FlexPod components, the cases are worked by engineers who know the whole solution, and it is positioned as a lower-cost support option.
Why the other options are wrong:
- C. A description of the problem is still needed when a case is opened.
- D. Customers still open cases; not every issue is reported automatically.
Question 14
Your environment currently has a 12-node NetApp cluster serving iSCSI. You need to add at least four more nodes to serve FC to your environment.
In this scenario, what should you do?
- A. You can safely add up to 4 more storage controllers in the current cluster
- B. You can safely add up to 6 more storage controllers in the current cluster
- C. You must create a new cluster with the new storage controllers
- D. You can safely add up to 12 more storage controllers in the current cluster
Show answer and explanation ▾
Correct answer: C
An ONTAP cluster that serves SAN protocols supports a maximum of 12 nodes. The existing 12-node iSCSI cluster is already at that limit, so the additional FC nodes must go into a new cluster.
Why the other options are wrong:
- A. The cluster is already at the SAN node limit, so four more controllers cannot be added.
- B. The cluster is already at the SAN node limit, so six more controllers cannot be added.
- D. The cluster is already at the SAN node limit, so twelve more controllers cannot be added.
Question 15
A customer wants to upgrade their code fabric between each site with a modular chassis switch that supports up to 400GbE per port to accommodate more business transaction volume.
In this scenario, which device would help them accomplish their objective?
- A. Cisco Nexus 9504
- B. Cisco Nexus 9332C
- C. Cisco MDS 9706
- D. Cisco Catalyst 9400
Show answer and explanation ▾
Correct answer: A
The Cisco Nexus 9504 is a modular chassis switch, and its line cards support port speeds up to 400GbE, which meets both requirements.
Why the other options are wrong:
- B. The Nexus 9332C is a fixed switch, not a modular chassis.
- C. The MDS 9706 is a Fibre Channel director and does not provide 400GbE ports.
- D. The Catalyst 9400 is a campus access chassis and does not provide 400GbE ports.
Question 16
You have a customer that wants to deploy a new data center environment and take advantage of server portability. You propose that they use Cisco UCS servers to take advantage of stateless computing operations.
In this scenario, which Cisco UCS feature would help the customer achieve their objective?
- A. SEL logs
- B. MAC address pools
- C. Service Profiles
- D. VSANs
Show answer and explanation ▾
Correct answer: C
A service profile holds the identity and configuration of a server, such as addresses, firmware and boot policy, separately from the hardware. Moving the profile to another blade moves the server identity with it, which is what makes Cisco UCS compute stateless and portable.
Why the other options are wrong:
- A. SEL logs record hardware events and do not move a server identity.
- B. MAC address pools supply addresses to a profile but do not provide portability by themselves.
- D. VSANs separate Fibre Channel fabrics and do not define a server.
Question 17
A customer has configured a FlexPod solution and is experiencing issues with connectivity from the Cisco Nexus switches to the NetApp AFF controllers. The customer must verify connectivity using the FC protocol.
What are two ways to troubleshoot this problem? (Choose two.)
- A. Use the WWNN
- B. Use the WWPN
- C. Use the FCID
- D. Use Domain ID
Show answer and explanation ▾
Correct answer: B, C
FC connectivity is verified per port. The WWPN of each initiator and target port should appear in the fabric login and name server tables, and the FCID assigned at login confirms that the port has joined the fabric.
Why the other options are wrong:
- A. A WWNN identifies the whole node, not the individual port being checked.
- D. A Domain ID identifies a switch in the fabric, not an end device connection.
Question 18
A customer plans to decommission a Cisco UCS B-Series server, as part of this action, the customer disassociates the service profile from the currently assigned server.
Which action is performed by UCS Manager in this scenario?
- A. It reboots the primary Fabric Interconnect immediately
- B. It recalculates the power allotment for each blade server within the chassis
- C. It reboots the secondary Fabric Interconnect immediately
- D. It powers down the server
Show answer and explanation ▾
Correct answer: D
When a service profile is disassociated, Cisco UCS Manager shuts down the server and removes the identity and configuration that the profile applied, leaving the hardware unassigned.
Why the other options are wrong:
- A. Disassociating a service profile does not reboot the primary Fabric Interconnect.
- B. Recalculating chassis power allotment is not the action taken on disassociation.
- C. Disassociating a service profile does not reboot the secondary Fabric Interconnect.
Question 19
You are designing a FlexPod solution with secure multitenancy for a company. Each department in the company wants to use their own storage and to be integrated with Windows Active Directory.
In this scenario, which three technologies should be included in the design? (Choose three.)
- A. IPspaces
- B. NVMe
- C. S3
- D. CIFS
- E. Storage Virtual Machine
Show answer and explanation ▾
Correct answer: B, D, E
Each department gets its own storage virtual machine as an isolated tenant, CIFS lets each of those SVMs join Windows Active Directory and serve authenticated shares, and NVMe is the third technology in this design, giving tenants high-performance block access.
Why the other options are wrong:
- A. IPspaces separate overlapping network address spaces and are not one of the three technologies in this design.
- C. S3 object storage is not what Active Directory integrated departmental storage calls for.
Question 20
Which Cisco UCS Fabric Interconnect model has multiple 100 Gbps ports available for use?
- A. Cisco UCS 6332
- B. Cisco UCS 6324
- C. Cisco UCS 6454
- D. Cisco UCS 6332-16UP
Show answer and explanation ▾
Correct answer: C
The Cisco UCS 6454 Fabric Interconnect includes six 40/100 Gbps QSFP28 uplink ports alongside its 10/25 Gbps ports.
Why the other options are wrong:
- A. The UCS 6332 provides 40 Gbps ports, not 100 Gbps.
- B. The UCS 6324 is the UCS Mini Fabric Interconnect and has no 100 Gbps ports.
- D. The UCS 6332-16UP provides 40 Gbps and unified ports, not 100 Gbps.
Question 21
You want to ass a customer’s NetApp storage controllers into their Cisco Intersight management portal.
In this scenario, which IP address would you choose to add?
- A. NetApp SVM management IP address
- B. NetApp Active IQ Unified Manager IP address
- C. NetApp cluster IP address
- D. NetApp Virtual Storage Console IP address
Show answer and explanation ▾
Correct answer: B
Cisco Intersight manages NetApp ONTAP storage through NetApp Active IQ Unified Manager, which is claimed as a target through an Intersight Assist appliance. The address entered is therefore the Active IQ Unified Manager address.
Why the other options are wrong:
- A. An SVM management address is not the target that Intersight claims for NetApp storage.
- C. The cluster address is not entered directly; Intersight reaches the cluster through Active IQ Unified Manager.
- D. Virtual Storage Console is a vCenter plug-in, not the target that Intersight claims.
That was 21 of 60.
The full NetApp NS0-175 pack has all 60 questions, each with the answer, the explanation and why the other options are wrong, plus a questions-only copy for timed runs. $39.00 USD, paid once, with free monthly updates and a pass-or-your-money-back guarantee.
Get the full packNot ready yet? Get the first 22 free as one PDF by email. Get the Half Pack →
About the NS0-175 exam
These 21 NetApp NS0-175 questions are free here. The free PDF has 22, free by email.
They are drawn from the same bank as the full NS0-175 pack, which has 60 questions in total.